core/quantities

VocabularyCoreDraft57 terms

What an amount describes: the codes for a Property's type, an Axis's quantity, an Emission's type, an Evidence's observed and a Criterion's metric. Each term states its unit and valid range.

Used by Axis, Criterion, Emission, Evidence, Property, Step and Trace.

General

  • time

    Time

    A point in time. As an axis, its coordinates are RFC 3339 date-times.

  • frequency

    Frequency

    UnitHzValuenumberRangeat least 0

    Frequency.

  • height

    Height

    UnitmValuenumber

    Height above the local ground.

  • depth

    Depth

    UnitmValuenumberRangeat least 0

    Depth below the local ground or water surface.

  • distance

    Distance

    UnitmValuenumberRangeat least 0

    Distance between two places.

  • easting

    Easting

    UnitmValuenumber

    The first coordinate of a projected coordinate reference system.

  • northing

    Northing

    UnitmValuenumber

    The second coordinate of a projected coordinate reference system.

  • longitude

    Longitude

    UnitdegValuenumberRange-180 to 180

    Longitude, east positive.

  • latitude

    Latitude

    UnitdegValuenumberRange-90 to 90

    Latitude, north positive.

  • angle

    Angle

    UnitdegValuenumber

    An angle with no fixed zero, such as an angle of incidence. A direction on the ground is a bearing.

  • bearing

    Bearing

    UnitdegValuenumberRange0 to 360

    A horizontal direction, in degrees clockwise from true north.

  • grid_bearing

    Grid bearing

    UnitdegValuenumberRange0 to 360

    A horizontal direction, in degrees clockwise from the grid north of the coordinate reference system.

  • record

    Record

    Valuestring

    A record of the document. As an axis, its coordinates are record ids, such as one coordinate for each source.

  • complex_part

    Complex part

    ValuestringOne ofrealimaginary

    The part of a complex amount: an axis with the coordinates real and imaginary.

Dimension

  • length

    Length

    UnitmValuenumberRangeat least 0

    Length of a record, such as a wall.

  • width

    Width

    UnitmValuenumberRangeat least 0

    Width of a record.

  • thickness

    Thickness

    UnitmValuenumberRangeat least 0

    Thickness of a record, such as a wall.

  • area

    Area

    Unitm2ValuenumberRangeat least 0

    Area of a record.

  • storey_count

    Storey count

    Unit1ValuenumberRangeat least 0

    The number of storeys of a building.

  • material

    Material

    Valuestring

    What a record is made of, such as concrete or steel.

Weather

  • air_temperature

    Air temperature

    UnitdegCValuenumberRange-80 to 60Height2 mForCondition, Assumption, Evidence

    Air temperature.

  • relative_humidity

    Relative humidity

    Unit%ValuenumberRange0 to 100Height2 mForCondition, Assumption, Evidence

    Relative humidity.

  • air_pressure

    Air pressure

    UnithPaValuenumberRange500 to 1100ForCondition, Assumption, Evidence

    Air pressure at the surface, not reduced to sea level.

  • precipitation_rate

    Precipitation rate

    Unitmm/hValuenumberRange0 to 500ForCondition, Assumption, Evidence

    Rain and melted snow over the interval.

  • snowfall_rate

    Snowfall rate

    Unitmm/hValuenumberRange0 to 500ForCondition, Assumption, Evidence

    Snowfall as liquid water over the interval.

  • cloud_cover

    Cloud cover

    Unit%ValuenumberRange0 to 100ForCondition, Assumption, Evidence

    Total cloud cover.

  • cloud_cover_low

    Low cloud cover

    Unit%ValuenumberRange0 to 100ForCondition, Assumption, Evidence

    Cloud cover below 3 km.

  • cloud_cover_mid

    Middle cloud cover

    Unit%ValuenumberRange0 to 100ForCondition, Assumption, Evidence

    Cloud cover from 3 to 8 km.

  • cloud_cover_high

    High cloud cover

    Unit%ValuenumberRange0 to 100ForCondition, Assumption, Evidence

    Cloud cover above 8 km.

  • temperature_profile_log

    Temperature profile, logarithmic coefficient

    UnitKValuenumberRange-20 to 20ForCondition, Assumption, Evidence

    The coefficient a_T of the temperature profile T(z) = T0 + a_T·ln(1 + z/z0) + b_T·z.

    Salomons (2001), Computational Atmospheric Acoustics

  • temperature_profile_linear

    Temperature profile, linear coefficient

    UnitK/mValuenumberRange-1 to 1ForCondition, Assumption, Evidence

    The coefficient b_T of the temperature profile; positive in an inversion.

    Salomons (2001), Computational Atmospheric Acoustics

  • wind_speed

    Wind speed

    Unitm/sValuenumberRange0 to 100Height10 mForCondition, Assumption, Evidence

    Mean wind speed.

  • wind_direction

    Wind direction

    UnitdegValuenumberRange0 to 360Height10 mForCondition, Assumption, Evidence

    The direction the wind comes from, in degrees from true north.

  • wind_gust

    Wind gust

    Unitm/sValuenumberRange0 to 150Height10 mForCondition, Assumption, Evidence

    The peak gust over the interval.

  • roughness_length

    Roughness length

    UnitmValuenumberRange0.00001 to 5ForCondition, Assumption, Evidence

    The aerodynamic roughness length z0 of the wind profile.

  • wind_profile_log

    Wind profile, logarithmic coefficient

    Unitm/sValuenumberRange-20 to 20ForCondition, Assumption, Evidence

    The coefficient a_u of the wind profile along the wind direction.

    Salomons (2001), Computational Atmospheric Acoustics

  • wind_profile_linear

    Wind profile, linear coefficient

    Unit1/sValuenumberRange-1 to 1ForCondition, Assumption, Evidence

    The coefficient b_u of the wind profile along the wind direction.

    Salomons (2001), Computational Atmospheric Acoustics

  • pasquill_class

    Pasquill stability class

    ValuestringOne ofABCDEFGForCondition, Assumption, Evidence

    The Pasquill–Gifford stability class, A very unstable to G very stable.

  • obukhov_length_inverse

    Inverse Obukhov length

    Unit1/mValuenumberRange-100 to 100ForCondition, Assumption, Evidence

    The inverse Monin–Obukhov length 1/L: positive when stable, 0 when neutral.

  • friction_velocity

    Friction velocity

    Unitm/sValuenumberRange0 to 5ForCondition, Assumption, Evidence

    The surface friction velocity u*.

  • sensible_heat_flux

    Sensible heat flux

    UnitW/m2ValuenumberRange-1000 to 1500ForCondition, Assumption, Evidence

    The surface sensible heat flux, positive from the ground into the air.

  • boundary_layer_height

    Boundary layer height

    UnitmValuenumberRange0 to 6000ForCondition, Assumption, Evidence

    The height of the atmospheric boundary layer.

  • shortwave_radiation

    Shortwave radiation

    UnitW/m2ValuenumberRange0 to 1500ForCondition, Assumption, Evidence

    Global horizontal shortwave radiation, the mean over the interval.

Terrain

  • elevation

    Elevation

    UnitmValuenumber

    The height of the ground above the vertical datum.

  • ground_type

    Ground type

    Valuestring

    What the ground surface is, such as grass, gravel or pavement.

  • land_cover

    Land cover

    Valuestring

    What covers the land, such as forest, crop or water.

  • slope

    Slope

    UnitdegValuenumberRange0 to 90

    The slope of the ground.

Operation

  • rotational_speed

    Rotational speed

    Unit1/minValuenumberRangeat least 0

    How fast a machine turns.

  • load

    Load

    Unit%ValuenumberRange0 to 150

    The share of rated output a machine runs at.

  • rated_power

    Rated power

    UnitkWValuenumberRangeat least 0

    The power a machine is rated for.

  • power

    Power

    UnitkWValuenumberRangeat least 0

    The power a machine runs at.

  • gas_flow_rate

    Gas flow rate

    Unite3m3/dValuenumberRangeat least 0

    Gas volume per unit time, at standard conditions.

  • liquid_flow_rate

    Liquid flow rate

    Unitm3/dValuenumberRangeat least 0

    Liquid volume per unit time.

  • operating_hours

    Operating hours

    UnithValuenumberRange0 to 24

    The hours a day a source runs.

  • fuel_type

    Fuel type

    Valuestring

    The fuel a source burns, such as natural gas or diesel.

Instrument

  • instrument_class

    Instrument class

    ValuestringOne ofclass_1class_2ForInstrument

    The class of a sound level meter, as IEC 61672-1.

    IEC 61672-1:2013

  • firmware_version

    Firmware version

    ValuestringForInstrument

    The version of the instrument's firmware.